OPERATING PROCEDURES
MP35.4543
10JUL97
LEVEL SENSING UNIT ADJUSTMENT
Level the vehicle by placing a circular bubble level in the center
are off. This is done by drawing up the corresponding screw if
With the vehicle level, adjust the sensing unit until all yellow lights
of the freezer floor or location within the vehicle that is to be level.
LEVEL SENSING UNIT
SURFACE
MOUNTING
BELOW THE SURFACE MOUNTING
SCREWS (3)
REAR
THIS
SIDE
STICKER
ON TOP
UP
SPRINGS (3)
the sensing unit is mounted below the surface, as shown, or
backing out the corresponding screw if the sensing unit is
mounted above the surface. Bump the sensing unit to see that
it has settled down in the level position.