SENSING UNIT MAINTENANCE/SERVICE
SENSING UNIT ADJUSTMENT / WITH ADJUSTING ENHANCEMENT
NOTE: If opposing LED's are lit, there is a problem with
the Sensing Unit.
If LED (A) is lit: Tighten adjustment screw number 1
until the LED is off.
If LED (C) is lit: Loosen adjustment screw number 1
until the LED is off.
If LED (B) is lit: Loosen adjustment screw number 3
until the LED is off.
until the LED is off.
If LED (D) is lit: Tighten adjustment screw number 3
09NOV10
MP44.1511
With the vehicle level according to the bubble level, if there
are no yellow lights lit on the Touch Panel, the sensing unit is
properly adjusted. If there are yellow LEVEL lights lit on the
Touch Panel, manual adjustments to the Sensing Unit are
needed.
SENSING UNIT ACCURACY TOLERANCE
The sensing unit has an accuracy tolerance of ± 5.4 inches front to rear and
INSTRUCTION SHEET
±1 inch side to side on a 36 foot vehicle. Typical leveling results will be better.
IMPORTANT: THE SENSING UNIT MOUNTING SPRINGS
SHOULD BE COMPRESSED ABOUT 1/2 THEIR FREE
LENGTH. SCREW NUMBER 2 SHOULD NOT BE TURNED
MOUNTED BELOW
FRONT
MOUNTING SURFACE
(3) MOUNTING
(3) MOUNTING
SCREWS
SPRINGS
THIS
SIDE
UP
LED A - FRONT OF VEHICLE
LED B - LEFT SIDE OF VEHICLE
LED C - REAR OF VEHICLE
LED D - RIGHT SIDE OF VEHICLE
REMOTE MOUNTED "POTTED" ELECTRONIC SENSING UNIT
WHILE ADJUSTING THE SENSING UNIT. AFTER
ADJUSTING THE SENSING UNIT, BUMP THE SENSING
UNIT TO SEE THAT IT IS SETTLED TIGHT AGAINST ALL
THREE SCREW HEADS AND STILL INDICATES THAT
THE UNIT IS LEVEL.
Level the vehicle by placing a bubble level in the center of the
freezer floor or upon whichever surface within the vehicle that
is to be level. It is best if the level is placed close to the
mounting area of the sensing unit. Using the Leveling System
and the bubble level, ignoring the yellow LEVEL lights on the
Touch Panel, level the vehicle until the bubble is centered.
The ignition (motorized units) or master power switch (towable
units) must be on. Remove the "Adjusting Enhancement Cap".
DO NOT LOSE THIS CAP.
There is a small pin beneath the
cap. Use a jumper wire with an alligator clip to apply a ground
to the pin. This will make the sensing unit very sensitive. The
yellow lights may "jump" around while adjusting the sensing unit.
Let the lights settle down after each adjustment. Small, gentle
turns will work best. Turn mounting screws 1 and 3 to adjust
the sensing unit. Turn screws as instructed to turn out all the
yellow LEDs. When all the LEDs are out, remove the jumper
wire and replace the adjusting enhancement cap. DO NOT
over tighten.
SENSING UNIT
BOTTOM VIEW OF
LED
3
D
C
LED
LED
A
B
YELLOW LEDs
2
MOUNTING/ADJUSTMENT
SCREWS (3)
1
LED
Move the vehicle to an unlevel position and level the
vehicle according to the yellow level sensing lights on
the touch panel. Readjust if necessary.
ADJUSTING
ENHANCEMENT
CAP