Installation and Maintenance Manual
24
Description of Functions Available in the User Menu
User 1 [Ct _] Close timer setting: This menu item is the automatic close timer for the gate. The
factory setting is zero, which is off. It may be configured up to 99 seconds.
User 2 [hC 0] Momentary Close: This menu item is to configure for the system for constant hold
push button Close function. The factory setting is zero, which is momentary contact input.
User 3 [ho 0] Momentary Open: This menu item is to configure for the system for constant hold
push button Open function. The factory setting is zero, which is momentary contact input.
User 4 [AP 0] Power loss function: This menu item only appears if the operator is a DC battery
powered version. This item is to configure what gate function will occur when the AC power fails.
See page 56 for more detailed information on DC operators.
User 5 [ro 0] Radio control option: This menu item is to configure whether a radio input can
open only (default) or if set to 1, also has the ability to close the gate when it is fully open.
User 6 [bF 2] Warn before operate: This menu item controls the warn before operate buzzer
and can be configured three ways. Setting the menu item to zero turns the buzzer off, but we
strongly advise leaving this valuable warning feature active to alert prior to gate motion. Never cut
the wires to the buzzer or unplug it. Set to 1 and the buzzer will sound three seconds before
motion and the entire time during gate motion. Set to 2 (default) and the buzzer will sound three
seconds before motion and for the first two seconds of motion.
User 7 [FA 0] Forced open Alert and automatic gate reposition: This function is intended for
highly secure facilities. If it is enabled, by setting the selection to 1, it will reinitiate a closure if a
gate is somehow forced to open far enough that the close limit switch releases. The Alert buzzer
will sound immediately, even if it had been turned off, and the motor will restart to secure the gate
fully closed. If the gate is not fully closed within four seconds the motor turns off and the alert
buzzer sounds an intruder alert for thirty seconds. The LCD display reads ALE1.
User 8 [dA 0] Drift Closed Alert and automatic gate reposition: If it is enabled, by setting the
selection to 1, it will restore a gate to back its fully open position if it drifts closed for any reason.
The buzzer will sound a warn before operate alert, even if it had been turned off, and the motor will
restart to reopen the gate. The motor will run for a maximum of four seconds and if the gate is not
fully open in this period, the buzzer sounds for ten seconds and the LCD display reads ALE2.
User 9 [PE 0] PE Alignment Mode: This feature may be activated as an aide to photo-eye
emitter / receiver alignment. The buzzer chirps once as the photo eye is triggered or twice when
the photo eye is released. The Alignment Mode is cancelled with any close limit input or reset input.
User 10 [CL 0] Clock and date set: The Smart Touch Controller is equipped with a 24 hour 365
day clock, so that events of significance can be logged and stamped with the time and date. This
feature is useful to record historical operation data, which can be accessed via the RS232 port. To
set or adjust the hour, minute, day or month, see page 29.
User 11 [Ld 5] LCD Contrast set: Under some extreme high or low temperature conditions, it
may be necessary to adjust the contrast of the LCD display. The display is adjustable from 0-9 with
a factory default setting of 5.