110
Issue 3.3.2 / April, 2011
Program 06-IP : Relay Assignment
06-000-01 Relay
00
IP = 01
System Default.
Item
Display
Pointer Data Description
-------- -------- ---------------------------
00(00) 00-06 Relay of MSU/MSC
xxxx 00-06 Relay of ACP (extension: xxxx)
Description:
MSU/MSC card and ACP device have 1 dry contact relay.
No voltage is provided by the system, the installer will have to provide their own source to suit the
application. Only use the relays to switch 24V DC / 90V AC at 1A. They are only designed for low
voltage control circuits. All Relays are Normally Open contacts and will close on activation of the function
for which they have been programmed.
Assign the required Relays one of the following functions.
Set data
Function
00 No Operation
01 Music On Hold
02 Door open
03
Reserved for future use
04 Trunk loud bell
05 Station loud bell
06 System Alarm
10
All Paging
MSU/MSC card and ACP device have 1 dry contact relay.
Summary of Contents for G1E
Page 16: ...Issue 3 3 2 April 2011 ...
Page 26: ......
Page 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Page 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Page 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Page 74: ...58 Issue 3 3 2 April 2011 ...
Page 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Page 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Page 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Page 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Page 127: ...G1E Programming Manual 111 ...
Page 169: ...G1E Programming Manual 153 ...
Page 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 218: ......