182
Issue 3.3.2 / April, 2011
Program 95-tk-IP : Trunk Specifications – 3
95-tk-IP TK SPEC
0 0 0 0 0 0 0 0
tk = 01-12, IP = 01-08
System Default
Item
Display
Pointer
Data
Programming Data Description
Default
-------- ----------
------------------------------------------------
-------------
01
0-1
Detect Fax Signal
0=Disable
02
0-
Reserved
0=
03
0-8
Trunk Call Duration
0= Disable
04
0-8
DISA and ECF – Lunch Time Delay
0=No
05
0-
Reserved
0=
06
0-9
Duet (Distinctive Ring) Setting
0=No Duet
07
0-
Reserved
0=
08
0-
Reserved
0=
General:
This program permits each trunk line to be assigned different parameters.
Description:
01. Detect Fax signal
This parameter enables a line to detect the Fax CNG tone and if present the line will be transferred to the SLT
port that is allocated as a fax port in Mode 43-cn-02.
Once the SLT port is set as a Fax port (43-CN-02 = T )press [MSG] for T then enable DISA for that line and Fax
detection will be enabled.
0 = Disable
1 = enable
Owing to difficulties with certain types of fax machines this feature is not supported or recommended.
02. Reserved:
03. Trunk Call duration:
This parameter enables the ability to control the length of individual calls on each trunk to the settings as follows
0 = No cutoff
1 = 3 Mins
2 = 5 Mins
3 = 10 Mins
4 = 15 Mins …… 8 = 50 Mins.
04. DISA and ECF Lunch Time setting:
During Lunch time setting the system will follow the settings for DISA or ECF night set in Mode 35-tk-03/04 if the
following settings are set to either DISA or ECF. If set at default (0) then no DISA or ECF will take place even if
ECF or DISA is set for night time.
0 = Disable
1 = DISA
2 = ECF
Summary of Contents for G1E
Page 16: ...Issue 3 3 2 April 2011 ...
Page 26: ......
Page 30: ...14 Issue 3 3 2 April 2011 G1E Main Equipment with MSC VMC 2 TKU s 2 STU s Installed ...
Page 31: ...G1E Programming Manual 15 G1E Main Equipment ...
Page 69: ...G1E Programming Manual 53 PROGRAMMING INFORMATION ...
Page 74: ...58 Issue 3 3 2 April 2011 ...
Page 75: ...G1E Programming Manual 59 PROGRAM MODES ...
Page 117: ...G1E Programming Manual 101 07 Reserved 08 Reserved ...
Page 119: ...G1E Programming Manual 103 07 Reserved 08 Reserved ...
Page 121: ...G1E Programming Manual 105 07 Reserved 08 Reserved ...
Page 127: ...G1E Programming Manual 111 ...
Page 169: ...G1E Programming Manual 153 ...
Page 171: ...G1E Programming Manual 155 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 218: ......