background image

 

 
 
 
 
 
 
 

 

       

 

 

 

 

  

 

 

 
 

   GDS-1280N 

       

 

 

 

 

    

 

 

1280 Ports 
Enterprise Class 
Communication System 

 

Installation Manual 

 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for GDS-1280N

Page 1: ...GDS 1280N 1280 Ports Enterprise Class Communication System Installation Manual ...

Page 2: ...elecom makes no warranty or representation either express or implied with respect to merchantability or fitness of its products for a particular purpose 2007 Auto Telecom Company Ltd This document or any parts thereof are not to be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or information storage and retrieval systems for any pur...

Page 3: ...ent and shall be easily accessible 9 This product is equipped with a three wire grounding type plug this plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 10 Do not allow anything to rest on the power ...

Page 4: ...E TELEPHONE LINES 1 COMPATIBILITY OF THE TELEPHONE NETWORK AND TERMINAL EQUIPMENT 2 RADIO FREQUENCY INTERFERENCE 2 CTR 21 98 482 EC DECLARATION NETWORK COMPATIBILITY 2 ISDN INSTALLATION 2 KEY HIGHLIGHTS OF THE GDS 1280 3 EASY INSTALLATION 3 BENEFITS 3 FLEXIBILITY OF SYSTEM APPLICATIONS 4 VARIED EXTENSION ALTERNATIVES 4 LIQUID CRYSTAL DISPLAY 4 TYPE OF PHONES 5 TYPE OF PHONES 6 MECHANICAL SPECIFICA...

Page 5: ...CABINET CABLING AND CONNECTION 15 DIP Switch Adjustment 19 POWER SUPPLY VOLTAGE OPTIONS FOR THE UNIT 21 POWER ON AND OPERATIONAL TEST IMPORTANT 21 OPERATIONAL TESTS IMPORTANT 21 STANDARD CARD INTRODUCTION 22 G2 MBU16 Front 22 G2 MBU16 Back 22 G2 MPU16 23 G2 MHU16 24 G2 MXU16 25 G2 PSU16 26 G2 MEUN16 27 ...

Page 6: ......

Page 7: ...nt The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called In most but not all areas the sum of the REN s of all devices connected to one line should not exceed five 5 0 To be certain of the number of devices you may connect to your line as determined by the REN you should contact yo...

Page 8: ...tions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class A computing device in accordance with the specification in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However this is no guarantee that interference will not occur in...

Page 9: ...ffective and complete communications solution for cost conscious companies on the cutting edge GDS1280 An Expansion of GDS 600 Key highlights of the GDS 1280 Easy Installation Factory Ready All GDS 1280 Telephone systems are ready to go right out of the box A well thought out default database is factory installed on each system which meets the needs for most installations This alleviates hours of ...

Page 10: ... ISDN phone proprietary HYBREX DK series Keyphone Access Control Phone ACP Door Phone and conventional industry standard single line sets Modem Answering Machine Cordless phone etc Liquid Crystal Display The DK1 DK2 DK3 DK6 Series Telephone Model DK1 21 DK2 21 is equipped with a large easy to read LCD display The LCD is 32 characters total comprised of 2 rows by 16 characters each The DK2 Series T...

Page 11: ...GDS 1280N General Description 5 HYBREX Telephone Model DK1 21 DK2 21 ...

Page 12: ...CE Key Telephone 26 AWG 200 m 24 AWG 300 m Single Line telephone 26 AWG 1000 m 22 AWG 3000 m Doorphone 24 AWG 300 m Music Source Input Impedance 600 ohms Maximum Input 0 775 VRMS INTERNAL RELAY CONTACTS Type SPST Rating 1 AMP 24VDC Function Door Switch Music on Hold etc CABLE REQUIREMENTS CO PABX Line Twisted 1 Pair 2 wires ISDN BRI Twisted 2 Pair 4 wires ISDN PRI Twisted 2 Pair 4 wires DK1 DK2 DK...

Page 13: ...T DIMENSIONS 438 mm W 411 mm D 107 mm H 17 2 16 2 4 2 WEIGHT 15 Kg 33 lbs Environmental Specifications OPERATING CONDITIONS STORAGE CONDITIONS Temperature 0º to 45º C 40º to 66º C 32º to 113º F 40º to 150º F Humidity 10 to 95 relative 10 to 95 relative Non condensing non condensing ...

Page 14: ... Digit Flexible Time Format 12 24 Hour Forced Account Code Assignment Intercom Intercom Single Digit Assignment Intercom Ring Voice Select Intercom Dialing Restriction ISDN Call Charge Metering Information Caller Identification Direct Inward Dialing Call Forward Internal External Call Waiting MSN Multiple Subscriber Number Sub addressing User to User Signaling Host PABX Access Hot line Line Group ...

Page 15: ...en Loop Timed Flash Hands free Answer Back Hearing Aid Compatibility Headset Compatibility Hold Exclusive System Hold Recall I Hold Indication I Use Indication Intercom Intercom ring voice interchange Intercom Step Call Intercom Voice Announce Last Number Redial Message Waiting Multi Language Display On Hook Dialing Prime Line Select Privacy Privacy Release Private Line Pulse Tone Conversion Ring ...

Page 16: ...t System G2 PWU16 Single Power Supply for G2 MMD1280 Master Device The system module includes the following cards G2 PSU16 Power Supply Unit G2 MBU16 Mother Board G2 MHU16 Main HDLC Data Exchange Unit G2 MXU16 Main PCM Voice Exchange Unit G2 MPU16 Main CPU Unit Standard Peripheral Card Model Description G2 MEU16 Main Expansion Unit Optional Cards Model Description G2 PSU16 Power Supply Unit Option...

Page 17: ...step The GDS 1280 system should be installed in strict accordance with this manual Key Service Unit which includes Power Supply Unit G2 PSU16 Mother Board G2 MBU16 Main HDLC Unit G2 MHU16 Main Exchange Unit G2 MXU16 CPU Unit G2 MPU16 Standard Peripheral Card Main Expansion Unit G2 MEU16 2 pcs are included To be installed in Cabinet 1 and 9 Optional Cards CPU Unit G2 MPU16 for redundant central con...

Page 18: ... 2 8 Normal Jump of normal status setting 9 Default Jump setting of default setting 10 Stop Shutdown MMD1280 11 Reset Restart MMD1280 12 Next G2 MPUN16 for CPU redundancy Optional Front Panel of G2 MXUN16 and G2 MHUN16 1 Port numbers for PCM An illustration for PCM port numbers 16 ports for PCM for connection to PCM 2 Port numbers for HDLC An illustration for HDLC port numbers 16 ports for HDLC fo...

Page 19: ...iring and optional Battery Backup cabinet AC LINE AC line should be dedicated exclusively to the system POWER OUTLET Power Outlet must be a 3 wire grounded outlet plug having parallel blades and ground pin Input power Line capacity requirements 10 amperes SURGE PROTECTION A Surge Protector is recommended on the dedicated AC line VENTILATION AND TEMPERATURE Humidity 10 to 95 relative non condensing...

Page 20: ...ou notice any damage to the packages please notify both the shipper and Auto Telecom or Authorized Dealers at once List of parts included in master device box Master Device for 1280 Port System Single Processor Single Power Supply 2 pcs of G2 MEUN16 cards 16 cables for PCM connection 3 meters long red color 16 cables for HDLC connection 3 meters long blue color Installation Guide 8 screws 2 pcs of...

Page 21: ...l Sticker of Numbers in the package box for you to mark those cables So we strongly recommend you to do as the followings before cabling the cabinets Below picture is the Label Sticker of numbers 1 16 You will find 5 sets of it in the box Normally you only need 4 sets The fifth set is spare Below picture is an example of marking the number of cabinet cable You may do the same way for cabinet 2 3 4...

Page 22: ...For Cabinet 1 1 Install the G2 MEUN16 card in the G2 MPU slot at cabinet 1 2 Connect to G2 IXU and to PCM Port 1 with red cable 3 Connect to G2 IPU and to HDLC Port 1 with blue cable ...

Page 23: ...For cabinet 9 1 Install the G2 MEUN card in the G2 MPU slot at cabinet 9 2 Connect to G2 IXU and to PCM Port 9 with red cable 3 Connect to G2 IPU and to HDLC Port 9 with blue cable ...

Page 24: ...ets 1 Connect G2 IXU to PCM port with red cable 2 Connect G2 IPU2 to HDLC port with blue cable Note Above picture is an example for cabinet 2 Please connect the other cabinets 3 4 5 6 7 8 10 11 12 13 14 15 16 accordingly ...

Page 25: ...e table on the mother board See the below picture For the 1st and 9th cabinet For the 2nd and 10th cabinet For the 3rd d and 11th cabinet For the 4th and 12th cabinet For the 5th and 13th cabinet For the 6th and 14th cabinet For the 7th and 15th cabinet For the 8th and 16th cabinet You will find this table on the GDS mother board G2 MBU Please follow the instruction to adjust the DIP Switch ...

Page 26: ...n and Cabling Only for reference We suggest you install the GDS 1280 main service unit on the top of the rack PCM1 16 ports GDS 1280 Unit HDLC1 16 ports G2 IPU2 and G2 IXU For other cabinets G2 MEUN16 for Cabinet 1 and 9 ...

Page 27: ... on LCD If one of the IPU does not appear it means the IPU is not connected 3 Check the CPU1 LED on GDS1280 unit is flashing steadily 4 Check DIP Switch in each cabinet is adjusted correctly 5 Check the web programming site Use IE browser to enter the System Programming Technical Information Please refer to GDS600 programming manual You will see V mark at the Switch Test State If you see an X mark...

Page 28: ...Socket to connect to the main CPU unit G2 MPUN16 CN5 3 CN3 Socket to connect to the main Exchange unit G2 MXU16 CN3 4 CN4 Socket to connect to the main HDLC unit G2 MHU16 CN4 G2 MBU16 Back 1 CN5 Socket to connect to the main Power unit G2 PSU16 CN2 2 CN6 Socket to connect to the main Power unit G2 PSU16 CN2 ...

Page 29: ...t at Normal position unless you need default setting 4 LED flash green slow CPU2 is working normally 5 LED flash green slow CPU1 is working normally 6 LED green light on PLL data is locked 7 LED red light on PLL is working normally 8 LED green light on LAN port is plugged 9 RS232 port 10 LAN port 11 4GB USB DEC Embedded Disk Card ...

Page 30: ... Board unit G2 MBU16 CN4 2 Please see below picture 3 Please see below picture 1 8 Ports to connect to Cabin 1 8 for HDLC 9 16 Ports to connect to Cabin 9 16 for HDLC 17 CN3 Socket to connect to the main Mother Board unit G2 MBU16 CN4 Top View Front View ...

Page 31: ...r Board unit G2 MBU16 CN3 2 Please see below picture 3 Please see below picture 1 8 Ports to connect to Cabin 1 8 for PCM 9 16 Ports to connect to Cabin 9 16 for PCM 17 CN3 Socket to connect to the main Mother Board unit G2 MBU16 CN3 Front View Top View ...

Page 32: ...G2 PSU16 1 CN2 Socket to connect to G2 MBU16 CN5 6 1 ...

Page 33: ...with red cable 3 Connect to G2 IPU HDLC with blue cable 4 HDLC connection to GDS1280 KSU of HDLC Port 1 or Port 9 with blue cable 5 SW1 select cabinet 1 or cabinet 9 please don t select 2 8 6 Socket to connect to the G2 MPU slot of Cabinet 1 or 9 Note 2 pcs of G2 MEUN16 are separately packed in the package ...

Page 34: ...TAIWAN www hybrex com AUTO TELECOM AUSTRALIA PTY LTD Unit 7 3 Gibbes Street Chatswood NSW 2067 www hybrex com au AUTO TELECOM NEW ZEALAND LTD PO Box 75 614 Manurewa Auckland New Zealand www hybrex com nz All data and specifications are subject to change without notice P N 5523 4920 0000 ...

Reviews: