Product Instruction Manual

Sapphire

SAPUC1

Undersink chiller

V19,1.

3

Summary of Contents for Sapphire SAPUC1

Page 1: ...Product Instruction Manual Sapphire SAPUC1 Undersink chiller V19 1 3 ...

Page 2: ...pecified on the rating plate The unit should be installed with easy access to the electrical plug This appliance should be installed indoors on a flat surface Install the appliance in a dry well ventilated area keep the ventilation openings on the sides and front of the unit uncovered and unobstructed with at least 10cm space from any surfaces This appliance can be used by children aged from 8 yea...

Page 3: ...t cut and not to crush the ends of the pipe as this may cause the connection to fail A brass adapter and plastic connector are provided to connect the pipe to 15mm mains supply copper pipe Two identical connectors are provided to connect the pipe to the WATER IN inlet on the chiller and then to connect a new run of pipe from the WATER OUT outlet of the chiller to the desired tap cold water dispens...

Page 4: ...en 8 and 12 minutes for the full capacity of the tank OFF COLD 1 2 3 4 5 6 C O L D E R 7 C 8 C 10 C 5 C 6 C 4 C Do not connect the electrical supply until the commissioning has been completed Electrical connection Connect the kettle style lead to corresponding socket located at the rear of the appliance before plugging the other end into an electrical socket Ventilation Depending on the installati...

Page 5: ...unit simply unscrew the drain nut located on the underside of the chiller ensure the drain seal is retained in the drain nut When the unit is drained replace the drain nut and seal and then follow the commissioning section of this instruction when reinstating Sanitising the unit First drain down unit as per the Draining the unit section Ensure the drain nut and seal are replaced before adding the ...

Page 6: ... H 10 C Minimum supply pressure 0 1 MPa Maximum supply pressure 0 3 MPa Connections Inlet Outlet push fit Refrigerant R134a 110g Operating ambient min max 100 C 380 C 360mm 265mm 370mm Approvals Immediate draw off 3 litres CE WRAS If pressure is above 3 bar then a pressure reducing valve is required ...

Page 7: ...a replacement product Incorrect installation and frost damage or failure to follow correct operating and maintenance instructions are excluded Consequential costs such as labour charges or damage to surroundings are expressly excluded Contact us If you experience a problem with this product you should first contact our service department on 01924 225 200 before taking any further action Experience...

Page 8: ...rking life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separ...