HY17S68 Series
HY17S68-DK03 IDE
Hardware User’s Manual
© 2020 HYCON Technology Corp
APD-HY17PIDE007-V01_EN
page10
(5)
J15: uA/mA Jumper
Function: measuring current usage
J15
∘
∙
∙
Right shorted, current
range mA measurement
∙
∙
∘
Left shorted, current
range uA measurement
(6)
LCD pin (4COM*36SEG)
Function: Mainly control the use of LCD display
(7)
VSS Test point
Function: Use for grounding test
(8)
Reset pin
Function: Reset ICE to use.
(9)
J3:VDD Jumper
Function: Provide HY17S68 power supply (4.5V)
(10)
IC: HY17S68
Function: Simulation chip, used to simulate the use of HY17P68
(11)
~ (14) Configure jumper
Function: According to different measurement functions, the configuration settings of
Jumper are as follows:
Function
J13
J14
J9
J8
J15
DC mV
AC mV
Open
Open
Short
Open
Open
DCV
ACV
Short
Open
Open
Open
Open
DC Current
AC Current
Open
Open
Open
Open
∘
∙ ∙
mA
measurement
∙ ∙
∘
uA
measurement
Resistor
Open
Open
Short
Short
Open
Continuity
Open
Open
Short
Short
Open
Diode
Open
Open
Short
Short
Open
Capacitor
Open
Open
Short
Short
Open
Frequency
(CNT Input)
Open
Short
Short
Short
Open
Thermocouple
Open
Open
Short
Open
Open