3.18
MITSUBISHI FX3U 48MR INPUTS AND OUTPUTS
PLC status indicators:
POWER
On when power exists to the PLC.
RUN
On when the PLC is in run mode. If not, check the run/stop switch. It should be in the run position.
BATT V6 Battery low voltage. If this LED is on, then replace the PLC battery.
ERROR: Prog E - Flashing LED indicates a program error.
Cpu -E - LED on (Solid). Indicates a CPU error.
Input and output terminal identification:
The top row of LED’S correspond to the top row of terminals and the bottom row of LED’S correspond to the bottom row of
terminals.
If LED: IN #0 is illuminated, then this corresponds to INPUT X0
If LED: OUT #17 is illuminated, then this corresponds to
OUTPUT Y17
INPUT TERMINALS
OUTPUT TERMINALS