3.22
Description Definition
Value
SPEED CONST
Blade speed adjustment number.
WHEEL TARGETS
Number of targets per revolution of the idler wheel. Can be toggled either 1 or 6.
HEIGHT CALIBRATION
This is to be used only if calibration is required.
ACTUAL HEIGHT
Actual Height Value. This value represents the head full stroke height.
HEIGHT CONSTANT
Specifies linear distance of head movement in inches per one pulse of head encoder.
LENGTH CALIBRATION
This is to be used only if calibration is required.
ACTUAL LENGTH
Value entered after performing length calibration procedure.
LENGTH CONSTANT
Specifies linear distance of shuttle movement in inches per one pulse of shuttle encoder.
ACCELERATION DISTANCE
Distance, in inches, the shuttle will travel slowly before reaching fast speed while
starting to move in either direction. (i.e. 1.000).
DECELERATION DISTANCE
Distance, in inches, the shuttle will travel slowly reaching before home or target position.
MINIMUM FAST DISTANCE
If the programmed length is smaller than this parameter, the shuttle will only move in
slow speed.
TARGET WINDOW
All/- tolerance from programmed length.
FRONT VICE OPEN DWELL
Delay time for the opening of the fixed VISE in seconds.
SHUTTLE VICE OPEN DWELL
Delay time for the opening of the shuttle VISE in seconds.
VICE CLOSE TIME
Delay time for the closing of the shuttle or fixed VISE in seconds.
FEED RATE
Activates feed rate display. Not active on S20A, S23A and H10 machines.
ACTUAL POSITION
If this value is set to “YES,” displays shuttle vise actual position.
HOLD SHUTTLE HOME
Hold shuttle VISE home and closed during cut.
BROKEN PROXIMITY SWITCH
Allows user to override signal from proximity sensor in case it is broken.
MINIMUM BLADE SPEED
Minimum blade speed on which the PLC will detect the that blade is running.
SPEED PROXIMITY SW. DELAY
Delay in monitoring of the blade speed proximity sensor during acceleration of the
blade from start to desired speed set by the potentiometer.
POWER DOWN TIMER
If “0” selected, then the machine will shut down after the job is completed. Range is
from “0” to “180” minutes.
BLADE CLEAR
If set to “YES,” when the AUTO cycle reaches the function of head up, the shuttle
will retract the material from the blade by 1/8” before the head will move up. When
the head reaches the up position the next length of material is shuttled into position.
TRIM CUT
If “YES” selected the machine will perform a facing cut of the material at the
beginning of an automatic cycle.
OUT OF STOCK
Selecting “yes” activates the out of stock option.
COOLANT
When “BLD” selected, coolant flows when the blade is running. When “BLD+ DWN”
selected, coolant flows when the blade is running and head is moving down.
QUEUE
The queue allows the operator to run several jobs (max 5) in series. If “REPEAT” is
selected the above series will be executed the selected number of times.
H-18A, H-22A Parameter Definitions & Values
PLC PARAMETER DEFINITIONS & VALUES
Summary of Contents for H18 A
Page 2: ......
Page 12: ...0 8 Item 391938 Chip Augar Item 391335 Item 391340 ...
Page 13: ...0 9 Item 391397 Item 392801 Fixed Vise Shuttle Vise Item 392801 ...
Page 14: ......
Page 16: ...1 2 LIFTING INSTRUCTIONS ...
Page 59: ...4 1 ELECTRICAL SCHEMATICS SEE PDF ON ATTACHED CD SECTION 4 ELECTRICAL ...
Page 60: ...4 2 ...
Page 64: ...6 2 ...
Page 65: ...7 1 SECTION 7 OPTIONS OPTIONAL ASSEMBLY DRAWINGS SEE PDF ON ATTACHED CD ...
Page 66: ...7 2 ...
Page 69: ...8 3 H18SV H22SV LIFTING INSTRUCTIONS ...
Page 70: ...8 4 H18SV LAYOUT ...
Page 71: ...8 5 H22SV LAYOUT ...
Page 72: ...8 6 ...
Page 74: ...9 2 ...