EDS 3000 IO-Link
27
Edition: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Part no.: 669897
20.2 EDS 3000 with ceramic sensor cell; absolute and relative pressure up
to 16 bar (500 psi)
EDS 3 4 X 6 - F31 - XXXX - XXX
Version (technology)
4
= Thin film DMS relative
Mechanical connection
4
= G1/4 A ISO 1179-2 (DIN 3852)
(only in conjunction with pressure range in bar)
7
= 9/16-18 UNF 2A (SAE6), male thread
(only in conjunction with pressure range in psi)
9
= Threaded port DIN 3852-G1/4
(only in conjunction with pressure range in bar)
Electrical connection
6
= Male M12x1, 4 pole
(mating connector not supplied)
Output
F31 = IO Link interface
Pressure range
In bar: 0040; 0100; 0250; 0400; 0600
In psi: 1000; 3000; 6000; 9000
Modification number
000 = Standard in bar
400 = Standard in psi