38
EDS 3000 IO-Link
Edition: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Part no.: 669897
Variable "Primary Value Display Unit" index=76 id=V_PrimaryValueDspUnit
data type: 8-bit UInteger
allowed values: 0 = bar, 1 = psi, 2 = MPa
default value: 0
access rights: rw
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "Primary Value Range" index=80 id=V_PrimaryValueRange
data type: 72-bit Record (subindex access not supported)
access rights: ro
subindex
bit
offset
data type
allowed
values
default
value
mod.
other var.
name
description
1
56
16-bit Integer
0
Lower Value
2
40
16-bit Integer
2500
Upper Value
3
32
8-bit Integer
1
Decimals
4
0
4-octet String
UTF-8
"bar"
Unit
Variable "Primary Value" index=84 id=V_PrimaryValue
data type: 24-bit Record (subindex access not supported)
access rights: ro
dynamic
subindex
bit
offset
data type
allowed
values
default
value
mod.
other var.
name
description
1
8
16-bit Integer
0
Process Value
2
3
Boolean
true
Not Available
3
2
Boolean
false
Overflow
4
1
Boolean
false
Underrun
5
0
Boolean
false
Signal Error
Octet 0
bit offset
23
22
21
20
19
18
17
16
subindex
1
element bit
15
14
13
12
11
10
9
8
Octet 1
bit offset
15
14
13
12
11
10
9
8
subindex
1
element bit
7
6
5
4
3
2
1
0
Octet 2
bit offset
7
6
5
4
3
2
1
0
subindex
/ / / / / /
/ / / / / /
/ / / / / /
/ / / / / /
2
3
4
5