40
EDS 3000 IO-Link
Edition: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Part no.: 669897
ErrorTypes
Code
Additional
code
Name
Description
128 (0x80)
0 (0x00)
Device application error -
no details
Service has been refused by the device application and no
detailed information of the incident is available
128 (0x80)
17 (0x11)
Index not available
Access occurs to a not existing index
128 (0x80)
18 (0x12)
Subindex not available
Access occurs to a not existing subindex
128 (0x80)
32 (0x20)
Service temporarily not
available
Parameter is not accessible due to the current state of the
device application
128 (0x80)
33 (0x21)
Service temporarily not
available - local control
Parameter is not accessible due to an ongoing local operation
at the device
128 (0x80)
34 (0x22)
Service temporarily not
available - device control
Parameter is not accessible due to a remote triggered state of
the device application
128 (0x80)
35 (0x23)
Access denied
Write access on a read-only parameter
128 (0x80)
48 (0x30)
Parameter value out of
range
Written parameter value is outside its permitted value range
128 (0x80)
49 (0x31)
Parameter value above limit Written parameter value is above its specified value range
128 (0x80)
50 (0x32)
Parameter value below limit Written parameter value is below its specified value range
128 (0x80)
51 (0x33)
Parameter length overrun
Written parameter length is above its predefined length
128 (0x80)
52 (0x34)
Parameter length underrun Written parameter length is below its predefined length
128 (0x80)
53 (0x35)
Function not available
Written command is not supported by the device application
128 (0x80)
54 (0x36)
Function temporarily
unavailable
Written command is not available due to the current state of
the device application
128 (0x80)
64 (0x40)
Invalid parameter set
Written single parameter collides with other actual parameter
settings
128 (0x80)
65 (0x41)
Inconsistent parameter set
Parameter inconsistencies were found at the end of block
parameter transfer, device plausibility check failed
128 (0x80)
130 (0x82) Application not ready
Read or write service is refused due to a temporarily
unavailable application
129 (0x81)
16 (0x10)
Persistent memory error -
no details
Persistent memory access failed and no detailed information
of the incident is available
129 (0x81)
17 (0x11)
Parameter could not be
saved
Parameter could not be saved to persistent memory
129 (0x81)
18 (0x12)
Parameter could not be
loaded
Parameter could not be loaded or restored from persistent
memory
Process Data Formatting
Formatting for Process Data id=PI_PdIn
Subindex 1:
Subindex 2:
Subindex 3: * 0.1 + 0 bar Dec.1
HINWEIS / NOTE
:
Die Anzahl der Dezimalstellen ist abhängig von der Gerätevariante bzw. der
Druckstufe. /
The number of decimal places depends on the device variant or the
pressure level.