EDS 3000 IO-Link
41
Edition: 20.04.2020
HYDAC
ELECTRONIC
GMBH
Part no.: 669897
Events
Code
Type
Name
Description
36002 (0x8ca2) Error
User setup error
User setup is corrupt, device is running with factory settings
36016 (0x8cb0) Error
Primary value signal
error
Primary value update failed, device output is temporarily disabled
36032 (0x8cc0) Warning
Primary value out of
range
Primary value is below or above its valid range and limited to the
corresponding lower or upper value
36350 (0x8dfe) Error
System Test Event 1
IO-Link V1.1 system test event 1: event appears by setting index 2
to value 240, event disappears by setting index 2 to value 241
36351 (0x8dff) Error
System Test Event 2
IO-Link V1.1 system test event 2: event appears by setting index 2
to value 242, event disappears by setting index 2 to value 243