ETS 4100S IO-Link
7
Edition: 2020-07-20
HYDAC ELECTRONIC GMBH
Part no.: 670032
E
4.5 Organizational measures
The user manual always have to be kept accessible at the place of use of the measuring
system.
In addition to the user manual, generally applicable legal and other binding accident
prevention and environmental protection regulations must be paid attention to and have
to be mediated.
The respective applicable national, local and system-specific provisions and
requirements must be paid attention to and mediated.
It is mandatory for the operator to inform personnel on special operating features and
requirements.
The personnel instructed to work with the measuring system shall have read and
understood the user manual, especially the
chapter 4 Safety
The nameplates and any prohibition or instruction symbols applied on the measuring
system shall always be maintained in a legible state.
Repairs may only be undertaken by the manufacturer or a facility or person authorized
by the manufacturer.
5
Functions of the ETS 4100S
Depending on the model, the instrument has the following functions:
The parameterization as well as the detection of the measured values and the switch points
is performed by means of an IO-Link interface.
Supports IO-Link specifications V1.1
Supports SIO mode
Adaptation to the corresponding application using specific parameter settings
Switching outputs with parameterizable delay times
Switching of the switching outputs in accordance with the temperature and the pre-set
switching parameters
Storage of the measured min., max. and mean values
Provision of comprehensive device information and diagnostic options, i.e. device
temperature, measured channel-based events such as general measured channel-based
operation times, event counter, statistics of the actual benefit (operation per measured
range unit / values not met or exceeded, overload etc.)
6
Assembly
6.1 General installation instructions
The temperature sensor can be installed directly in the hydraulic system via the threaded
connection. Ensure the sensor element (inside of the probe in front of the thread) is immersed
in the flow of the fluid, otherwise, the reaction time will increase. The electrical connection
must be carried out by a qualified electrician according to the relevant regulations of the
country concerned (VDE 0100 in Germany).
The temperature sensor series ETS 4100S are
-marked. A declaration of conformity is
available on request. The relevant EMC standards EN 61000-6-1; EN 61000-6-2, EN 61000-
6-3, EN 6100-6-4 are met. However, the stipulations of those standards are met only if the
sensor's housing has been correctly earthed by a qualified electrician.