ETS 4100S IO-Link
17
Edition: 2020-07-20
HYDAC ELECTRONIC GMBH
Part no.: 670032
E
11 Technical data
Input data
Measurement range
-25 … +100°C
Probe length
mm
6
50
100
250
350
Probe diameter
mm
4.5
8
8
8
8
Pressure resistance
bar
600
125
125
125
125
Mechanical Connection
G 1/4 A ISO 1179-2
Tightening torque, recommended
20 Nm
Parts in contact with fluid
1)
Mech. connection: Stainless steel
Seal:
FKM
Output data
Switching outputs
PNP Transistor switching output (parameteriseable: PNP, NPN or
Push-Pull)
Option one further PNP transistor switching output
Switching current: max. 250 mA per switching output
Output signal
IO-Link V1.1
Accuracy at room temperature
± 0.1 °C bei -10 .. +85 °C
± 1.5 °C bei -25 .. +105 °C
Temperature drift
± 0.01 % FS / °C
Reaction time to DIN EN 60751
T
50
: ~ 4 s
T
90
: ~ 8 s
Smart Functions
Operational data logging
(resettable as well as persistent over the
whole life cycle)
Temperature (min / max / average value)
Operating times
-
General (hour counter)
-
Arrhenius value (temp. compensated operating time)
Measuring channel-related events
General measuring channel-related operating times
Event counter
Statistics for the actual use (operation per measuring range
segment / over/undershooting, overload etc.)
Communication
Via IO-Link
Environmental conditions
Operating temperature range
2)
-40 .. +85 °C / -25 .. +85 °C
Nominal temperature range
2)
-40 .. +100 °C / -25 .. +100 °C
Storage temperature range
-40 .. +100 °C
Medium temperature range
2)
-40 .. +125 °C / -25 .. +125 °C
mark
EN 61000-6-1 / -2 / -3 / -4
Vibration resistance acc. to
DIN EN 60068-2-6 at 0 .. 500Hz
25 g
Shock resistance acc. to
DIN EN 60068-2-27
20 g at 6 mm probe length
Other probe lengths on request
Protection type acc. to DIN EN 60529
3)
IP 65
Other data
Supply voltage
9 .. 35 V DC
(18 .. 30 V DC for communication operation)
Residual ripple of supply voltage
≤ 5 %
Current consumption
< 25 mA (without communication)
Weight:
~ 200 g (probe length 6 mm)
~ 215 g (probe length 50 mm)
~ 235 g (probe length 100 mm)
~ 280 g (probe length 250 mm)
~ 315 g (probe length 350 mm)