ETS 4100S IO-Link
Edition: 2020-07-20
HYDAC ELECTRONIC GMBH
Part No.: 670032
E
IO-Link specific data:
Features
Block Parameters
Yes
Data Storage
Yes (Data Storage Class 1)
Profile Characteristic
0x0001 (Device Profile: Generic Profiled Sensor),
0x4000 (Common Application Profile: Identification &
Diagnosis),
0x8001 (Function Class: Switching Signal Channel)
Supported Access Locks
Parameter (write)
Data Storage
Communication
IO-Link revision
V1.1
Port Class
A and B
Transmission Rate, Baud rate
38.4 kBaud (COM2)
Minimum cycle time
2.5 ms
Process data width
16 Bit (14 measured value- + 2 switching bits)
SIO Mode Supported
Yes
M-sequence capability
PREOPERATE = TYPE_1_V (8 0D-Bytes)
OPERATE = TYPE_2_2 (1 OD-Byte)
ISDU supported
IO Device Description (IODD) download at: https://ioddfinder.io-link.com/#/
Note: Reverse polarity protection of the supply voltage, overvoltage, override and and short circuit protection
are provided.
FS
(
F
ull
S
cale) = relative to the full measuring range
1)
Further sealing materials on request
2)
Standard version up to - 25 °C with FKM seal, - 40 °C on request
3)
With mounted female connector of the corresponding protection type, do not exceed the tightening torque
12 Model code
ETS 4 1 4 6 S – F31 – XXX – 000
Mechanical connection
4 = G 1/4 A ISO 1179-2, male thread
Electrical connection
6 = M12x1, 4-pol.
Enhanced functions
S= Smart
Output
F31 = IO-Link Interface
Probe length in mm
006; 050; 100; 250; 350
Modification number
000= Standard
Note:
For devices with a different modification number, please read the label or the technical
amendment details supplied with the instrument.