4 | Assembly, installation and commissioning
HYDAC FILTER SYSTEMS GMBH
38 / 60
MoWa CMP43x0-5 4191543c en-us print
Fig. 9:
Star delta connection
Star (Y) connection
Delta connection
Checking the direction of rotation.
Check the direction of rotation on the electric motor by
switching it on briefly (manual operation). An arrow on the fan
shroud / pump shows the correct direction of rotation
If it is necessary to modify the direction of rotation, then switch
the two phases in the terminal box of the electric motor.
1
2
3
4
5
6
7
8
A
Summary of Contents for CMP 43x0-5 Series
Page 60: ...www hydac com ...