FAM Description
FAM 5
en(us)
23 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
FAM features
The FAM is able to reduce fluids described in the chapter "Suitable fluids"
typically to the following attainable Residual water contents:
Hydraulic and lubrication oils
< 100ppm
Turbine oil (ISO VG32/46)
< 50 ppm
Transformer oil
(The FAM5 is not suitable for online or onload operation)
< 10 ppm
The typical dewatering rate is up to 0.8l/h at 1% (10,000 ppm) water content
(ISO VG32, 50
°
C).
Dewatering performance/Dewatering speed depends in particular on the oil
type, oil temperature, oil quantity, tank condition, water content and the
environmental conditions and can differ considerably from the indicated
values depending on use.
The dewatering speed is dependent on:
Dewatering
speed
Water content
Fluid temperature
Detergent additives