Switching on the heater / Checking setting (optional)
NOTICE
Oils with high viscosity
The pump will be damaged.
►
Switch the heater to approx. 50
°
C with oil of a viscosity
≥
350 mm
²
/s.
To increase the drainage performance, switch on the heater
even with oils of a viscosity
≤
350 mm²/s.
Set the desired heater temperature using the adjustment wheel. The heater
has a safety thermostat to protect against overheating. This switches off the
heater when it reaches 110°C. The safety thermostat has to be reset
manually.
See page 84 for details.
The markings on the adjustment wheel correspond with the desired heater
temperature in Celsius [°C].
-
= Heater OFF
F
= Setting for frost protection
30 … 80
= Heater temperature in °C