Performing maintenance
FAM 5
en(us)
84 / 100
BEWA FAM5 3667663b en-us 2012-12-12.doc
2012-12-12
Resetting the safety thermostat
If the heater reaches a temperature of 110°C, the safety thermostat will
trigger. The safety thermostat then needs to be reset manually. To do so,
proceed as follows:
Detach the cover from the heater:
1.
Stop the unit at the off switch and switch
off the FAM at the main switch.
2.
Pull out the plug / Disconnect the FAM
from the power supply.
3.
Let the unit / FAM and the heater cool
down.
4.
Pull the setting switch of the heater up and
off. And remove the two covering stoppers
of the screw holes.
5.
Unscrew and remove the two screws
(Torx 20).
6.
Pull the upper heater part up and out.
7.
Press the pin / lever (T) on the safety
thermostat with a small screwdriver.
8. Attach
the
upper
heater part onto the
heater from above.