Decoding model code
LVU-CD-40 /-T001
en(us)
Page 48 / 52
BeWa LVU-CD-40-T001 4142242a en-us 2016-05-13.doc
2016-05-13
Decoding model code
LVU - C D - 40 - G - N - 1 - 1 - E - z - BM - 1 / -
Type
LVU
= LowViscosity Unit
Function
C
= Filtering and coalescing
Operating fluid
D
= Diesel
Nominal flow rate
40
= 40 l/min
Pump version
G
= Gear pump
Supply voltage
M
= 230 V AC, 50 Hz, 1 Ph
N
= 400 V AC, 50 Hz, 3 Ph
X
= others (upon request)
Prefilter
1
= Prefilter size 10"
2
= Prefilter size 20"
Water drain
1
= Manual
2
= Automatic
Control type
E
= Eco
- with On/Off switch including motor protection
- visual clogging indicator
- manual water drainage
S
= Standard
- with On/Off switch including motor protection
- visual clogging indicator
- manual water drainage
- float switch in the collecting pan
- remote control input On/Off
P
= Standard
- with On/Off switch including motor protection
- programmable operating times
- electrical visual clogging indicator /
- automatic water drainage
- switch-off when "diesel dry"
- float switch in the collecting pan
- remote control input On/Off
-
= Without controller
Measurement technology
z
= without
Clogging indicator
BM = Differential pressure gauge, visual
D4 = Differential pressure indicator, visual/electrical
Type code
1
= (You always receive the latest type)
Additional
-
= without