Unit setup/connection
LVU-CD-40 /-T001
en(us)
Page 24 / 52
BeWa LVU-CD-40-T001 4142242a en-us 2016-05-13.doc
2016-05-13
Unit setup/connection
NOTICE
Danger of tipping over / danger of slipping due to vibrations
The unit will be damaged
►
Before starting it up, put the unit on a stable, horizontal surface.
Place the unit on a horizontal and level surface which is well ventilated.
Install the suction port connection at the lowest part of the tank. This ensures
that the water phase located at the base of the tank is reached.
Install the return line as far as possible from the suction point in order to
obtain an optimum intermixing of the tank contents.
Take the following steps to prepare the unit for operation:
1. Check that the power supply cable is undamaged. Replace damaged
cables immediately.
2. Check the connecting lines for leaks. Eliminate any leakages
immediately.
3. Check and insert the filter element. For details, see page 35.
4. Check and insert the coalescing element. For details, see page 38.
5. The unit is ready for the next steps on the following pages.