Unit setup/connection
LVU-CD-40 /-T001
en(us)
Page 28 / 52
BeWa LVU-CD-40-T001 4142242a en-us 2016-05-13.doc
2016-05-13
Connecting the main switch / E-STOP
Connect the main switch with the electric motor. The main switch also has a
motor protection switch matched to the electric motor to protect against
electrical overload.
In an emergency, use the main switch to disconnect the machine from the
mains voltage.
Connecting the water sensor
Connect the sensor according to the manufacturer's instructions.
You can find the manufacturer's documents for the water sensor in the
filtration unit's technical documentation.
Water sensor - monitoring signal
If the water sensor detects water for 5 seconds, then the water drain value
must be opened time-controlled for 10 seconds.
If the water sensor detects water for longer than 10 seconds, an error
message must occur, followed by switching off the unit.
Check the unit for a malfunctioning water drain valve or water sensor.
Replace any defective components immediately.
Connecting sensor in the collecting pan
Connect the sensor according to the manufacturer's instructions. The model
code of the sensor is 201120-3-48V-0.5A-10W
You can find the manufacturer's documents for the water sensor in the
filtration unit's technical documentation.
Sensor in the collecting pan - monitoring signal
If the sensor is activated in the collecting pan, then the unit must be switched
off.
Check the unit for leaks or incorrect triggering and/or water sensor or water
drain valve malfunctions.
Eliminate the leakages immediately and replace any defective components.