Performing maintenance
LVU-CD-40 /-T001
en(us)
Page 41 / 52
BeWa LVU-CD-40-T001 4142242a en-us 2016-05-13.doc
2016-05-13
12. Insert the new coalescing elements
into the element receptacles by
screwing them in carefully.
Do not use a hammer, etc.
13. Mount the element holding plate and
tighten the 3 wing nuts firmly.
14. Rotate the element set by 180°.
Insert the element set into the
coalescing housing.
Note that the element set fits only in
one position (Z) in the coalescing
housing.
15. Clean the sealing surface on the