Errors and troubleshooting
LVU-CD-10
en(us)
Page 56 / 68
BeWa LVU-CD-10 StdPrm 3993633a en-us 2015-08-26.doc
2015-08-26
Error
Cause(s)
Remedy
The suction hose is
not suitable for
negative pressure.
Use a hose that is resistant to
negative pressure.
The fluid is heavily
contaminated.
The contamination
retention capacity
of the filter element
has been reached.
Replace the filter element.
The viscosity of the
fluid is too high.
Check the viscosity of the fluid.
Heat the fluid to achieve the
permissible viscosity.
Filter contaminated
(The clogging
indicator appears)
The suction line at
the inlet is
generating too
much loss of
pressure.
Ensure that the pressure at the
inlet is within the permitted
range.
Leakage on the unit
/ filter housing
Empty the collecting pan and
eliminate the leak on the unit.
Wrong, missing, or
defective sealing
ring.
Check the sealing ring on the
filter element. Replace it if
necessary.
The cover on the
filter and coalescing
casing is not tight
enough.
Tighten the cover on the filter
and coalescing casing by hand.
Collecting pan too
full.
The water drainage
valve has a
malfunction.
The water drainage
valve jams.
Contact HYDAC.
The fluid is
dewatered.
No remedy required.
blinks
Error message from
filter and coalescing
casing.
Contact HYDAC.