MRFD2N
Calculating the pressure differential of the filter housing / filter element
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 17 / 32
MoWa MRFD2 3312153b en-us 2012-08-08.doc
2012-08-08
R (Resistance) Factors
Filter material
Abbreviation
= Designation
PA
= Polyamide
PP
= Polypropylene
PES
= Polyester
GF
= Glass fiber
Maximum differential pressure at the filter element
The maximum differential pressure
Δ
p
max
and the permitted temperature at the filter
element are:
Filter material
Fluid temperature
PP
PA
PES
-10 … 30 °C
4 bar
7 bar
8 bar
-10 … 60 °C
2 bar
5.5 bar
6.5 bar
-10 … 100 °C
-
3.5 bar
5 bar
Filter element FlexMicron P (Premium)
Aqueous fluids
oils
Filtration rating
PES*
PES*
GF**
1 µm
32.0
10.4
5.4
3 µm
24.0
7.5
-
5 µm
18.0
4.4
4.3
10 µm
17.0
1.8
3.2
20 µm
15.0
1.8
-
30 µm
14.0
0.9
-
40 µm
14.0
0.9
-
*
ß > 5,000
** ß > 20,000