Unit setup/connection
OFU-ATEX
en(us)
Page 30 / 56
BeWa OFU-ATEX 3838730 en(us) 2013-05-16
2013-05-16
Unit electrical connection
DANGER
Exposed electrical components in the switch
cabinet
Danger of fatal injury due to electric shock
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
The electrical connection of units without connection plugs to the power
supply module may only be performed by a technician with corresponding
knowledge and skills.
Compare the voltage and frequency specifications on the unit type label with
the existing network specifications.
Plug the power plug of the unit into a suitable power outlet.
The unit has a motor protection switch in the on/off switch. If the nominal
current is exceeded, the motor protection switch trips.
DANGER
Pump motor overheating
Risk of explosion/Danger of fatal injury
►
Connecting the pump motor to a frequency
inverter is not permitted.