Starting up the unit
OFU-ATEX
en(us)
Page 34 / 56
BeWa OFU-ATEX 3838730 en(us) 2013-05-16
2013-05-16
Starting up the unit
Inserting the filter element
The appropriate filter element is supplied. Insert the filter in the unit before
start up. Information on changing a filter element can be found on page 37.
Pre-filling the pump
If after approx. 2 minutes the unit does not convey any fluid, switch the motor
off and fill the unit using the suction hose.
Venting the filter housing
If the unit has started and is pumping properly, the filter housing has to be
vented. If the unit has started and is pumping properly, the filter housing has
to be vented. While the pump is running, loosen the vent plug (A) in the cover
plate of the filter housing. As soon as oil leaks out, retighten the plug.
Entlüftungsschraube
Vent each time the filter housing has run dry: after every filter element
change, and probably after a lengthy shutdown as well.