Disposing of the unit
OFU-ATEX
en(us)
Page 43 / 56
BeWa OFU-ATEX 3838730 en(us) 2013-05-16
2013-05-16
Disposing of the unit
Dispose of the packaging material in an environmentally friendly manner.
After dismantling the unit and separating the various materials, dispose of the
unit in an environmentally friendly manner.
Taking the unit out of operation
The unit is to be drained completely before being put into storage.
Pull out the power plug and secure the hoses and power cord to the unit.
Make sure to store the unit in a clean, dry place.
Errors and Troubleshooting
Error
Cause(s)
Remedy
Medium is heavily
contaminated
Replace the filter
element.
The contamination
retention capacity of the
filter element has been
reached.
Replace the filter
element.
Differential pressure
> 2 bar
The viscosity is too high
Warm the medium.
The pump is conveying in
the wrong direction.
Check the rotational
direction of the motor
and, if necessary,
reverse the phases.
No flow
The suction hose is
positioned above the
medium and sucks in air.
Sufficiently immerse the
suction hose in the
medium.
No function
The electrical connection
is faulty.
Check the electrical
connection, plug, cable
and socket.
Summary of Contents for OFU-10-P-2-N-2-B-05-B/-