Unit setup/connection
OXiStop OXS
en
Page 32 / 108
MoWa OXS 3992763e en-us 2018-08-10.docx
2018-08-10
Unit setup/connection
Observe the following points when setting up the unit:
- Keep an area facing upwards of at least 1.5 m above the unit
unobstructed for repair and maintenance purposes. It must also be
possible to access the individual components for repair and maintenance
purposes.
- Ensure that the respective tank securing measures are in place when
using hydraulic accumulators in the overall hydraulic system.
- Observe the permissible ambient temperature on the name plate of the
unit.
- Make sure there is sufficient ventilation around the area where the unit is
set up.
- Connect all electric components in accordance with the applicable
operating instructions.
Hydraulic installation of the unit
Connect the hydraulic tank to your hydraulic system at the corresponding
connections.
Optional: Connecting the heat exchanger
Connect your cooling circuit with the plate heat exchanger (A2->A1). In order
to achieve high thermal efficiency and high heat transfer rates, it is better to
install the plate heat exchanger in counter-flow direction.