Performing Maintenance
OXiStop OXS
en
Page 48 / 108
MoWa OXS 3992763e en-us 2018-08-10.docx
2018-08-10
Maintenance intervals
The inspection and maintenance work listed here is a necessary condition for
ensuring both long service life and error-free operation of the unit.
S
ee pag
e
24 h
our
s
/
d
a
ily
500 hour
s
/
m
ont
hl
y
300
0 ho
ur
s
/
ev
er
y
s
ix
m
ont
hs
600
0 ho
ur
s
/
ann
ual
ly
Unit
Check the unit for leaks (visual
check).
-
X
Check the screwed fittings to see
that they have been properly
resecured.
-
x
Check the pressure sensor on the
degassing unit and the fill level and
temperature sensors
-
X
Replacing the breather filter
X
Clean the suction strainer.
-
X
Check the AquaSensor (optional)
Check the ContaminationSensor
(optional)
Diaphragm
Checking the diaphragm (visual
check)
-
X
Replace the diaphragm.
For life cycle, see chapter
"Technical Data" on page 101
OLF 5 bypass flow filtration unit
Clogging indicator (visual)
X
Changing the filter element
Protective screen (optional)
X
Suction screen
X
Heat exchanger (optional)