MRFD7
Replacing the filter elements
14. Tighten the toggle screws with a 30 mm box
wrench crosswise with a maximum of 210 Nm
force.
15. Slowly open the pressure equalization valve (B).
A small output flow is removed from the active
output flow to fill the passive filter housing.
16. Close the pressure equalization valve (B).
17. Screw in the air bleed screw (C) on the cover.
18. The passive filter housing is now ready for
switching to active filtration.