OLF 10/2
Performing Maintenance
Changing the Filter Element
WARNING
Hydraulic system is under pressure
Bodily injury
►
Depressurize the system before performing any
work on it.
To change the filter, proceed as follows:
1.
Switch off the unit and make sure it cannot be
inadvertently switched back on.
2.
Close the shut-off valve (1) on IN inlet.
Depressurize the filter housing.
Unscrew the air bleed screw (2) out
completely in a counterclockwise direction
using a 6 mm Allen wrench.
3.
Drain the filter housing by opening the drain
ball valve (2).
Collect the escaping fluid (
≈
7 liters) in a
suitable container (1) and dispose of it in
accordance to local regulations.
HYDAC Filter Systems GmbH
en
Page 21 / 32
BeWa OLF10-2-TV 3494386 en 2009-09-16.doc