OffLine Separator - OLS
HYDAC Filtertechnik GmbH
en
Page 12
BEWA OLS 3329742a en.doc
2006-11-29
9.4
Drain water port connection
Connect the drain water port connection to an open downgrade pipe system or connect the
port to a receiver/can that regularly are emptied to a disposal drum.
If the drain water port is connected to a downgrade pipe system, it is
recommended to make a visual inspection point at the OffLine Separator OLS
e.g. with a funnel.
9.5 Electrical
connection
The electrical connection must be carried out by a qualified electrician. All
local and national electrical regulations and codes must be adhered to. If any
electrical or electromagnetic disturbances are likely in the supply system,
please inform the manufacturer.
•
The voltage, frequency and fuse size stated in specifications, must agree with the
installations at the electric power supply to the OffLine Separator OLS.
•
Turn the Main Switch to position "OFF" and connect the electrical power supply to the
control box according to the wire diagram.
•
Connect the electrical power supply and check that the correct voltage are
represented at the terminals.
•
If so, turn the Main Switch to position "ON" shortly and check direction of rotation on
the motor. The correct rotation is indicated by an arrow on the fan cover.
•
If the direction are wrong, disconnect the power supply, change two phases at three
phase motors or position of capacitor at single phase motors and re-connect the
electrical power supply.
If the OffLine Separator OLS are delivered without control box or manual motor
protection, care must be taken to protect the motor from overload.