Maintenance
FAM 5
en-US
Page 119 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
They should be replaced every year.
Since wear depends greatly on operating conditions, and replacement may
be necessary sooner under extreme conditions, we recommend inspecting
the vanes after 4000 operating hours.
Replacing the filter
1. Unscrew the housing cover (b).
2. Remove the filter cartridge (f) with seals (m, n) from the filter chamber
(g). Blow off the filter cartridge (see page 120) or replace it, then check
the seals.
3. Installation is the reserve of removal.
While doing so, observe that the seals (m, n) are not mixed up.
4. Ensure that the surfaces of housing (d) and rotor (c) are clean.
5. Tighten the screw(s) with 5.5 + 0.5 Nm