Error messages / Troubleshooting
FluidAqua Mobil - FAM10/15-P
en(us)
Page 101 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
25. Oil tank of rotary vane vacuum pump is too full -> drain oil
Cause:
The MAX switch point in the oil tank of the rotary vane
vacuum pump has been reached for 10 minutes. The
message appears on the display. The FAM goes into
the after-running phase and switches off.
Remedy: Perform
the
following
steps:
Step
Description
1. Message:
25. Oil tank of rotary vane vacuum pump is too full -> drain oil
2.
Empty the oil tank of the rotary vane vacuum pump until the level
in the inspection glass is between MIN and MAX. To drain, use
the drain ball valve on the vacuum pump.
3.
Actuate ESC key and reset failure with the F3 key.
4.
Start the unit by pressing the F1 key.
5.
The fault is repaired.
If the failure recurs, even though there is enough vacuum pump
oil in the rotary vane vacuum pump, first check the float switch
and afterwards the PLC.