Control panel basic (SIMATIC PANEL)
FluidAqua Mobil - FAM10/15-P
en(us)
Page 60 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
recurrent inspection interval runs again.
FTT
= Filter to
The fluid will only be filtered. The FAM
operates until a specified cleanliness code
has been reached (see page 56). Then the
FAM switches off. Now the recurrent
inspection interval starts (time until the unit
switches on again, see page 68). After this
has run through, the FAM switches on
automatically once again and runs for at least
≈
2 minutes. If the cleanliness code is
reached once again after this time, then the
FAM will switch off once again and the
recurrent inspection interval runs again.
FTT+H
= Filter to +
Heat
The fluid will be simultaneously filtered and
heated up to the prescribed temperature (see
page 55). Vacuum pump remains switched
off. The FAM operates until a specified
cleanliness code has been reached (see
page 56). Then the FAM switches off. Now
the recurrent inspection interval starts (time
until the unit switches on again, see page 68).
After this has run through, the FAM switches
on automatically once again and runs for at
least
≈
2 minutes. If the cleanliness code is
reached once again after this time, then the
FAM will switch off once again and the
recurrent inspection interval runs again.