Performing Maintenance
FluidAqua Mobil - FAM10/15-P
en(us)
Page 70 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Performing Maintenance
Before performing any maintenance work, pull out the plug on the FAM and
wind up the power cord to prevent the unit from being switched on again.
The Unit is to be disconnected from the power supply and protected against
being inadvertently switched back on when performing any maintenance,
servicing, inspection or repair work.
Once maintenance work is complete, check that the safety devices are still
working properly. Any screwed fittings which have been undone/removed are
to be checked to see that they have been properly resecured.
See page
24 hours /
daily
500 hours /
monthly
3000 hours
/
every six months
6000 hours
/
annually
FAM
Check the FAM for any leaks
(visual check).
-
X
Check the screwed fittings to see
that they have been properly
resecured.
-
X
Inspection of the measurement
technics /
Pressure sensor in the vacuum
column /
Differential pressure manometer at
the fluid filter /
AquaSensor at the IN port /
ETS at the vacuum column
(optional)
-
X
Check the fault indicator lamps /
perform a lamp test
X
Change Air filter
X
Clean the suction strainer.
X
Rotary vane vacuum pump
Checking the oil level
-
X
Changing oil
X