Performing Maintenance
FluidAqua Mobil - FAM10/15-P
en(us)
Page 76 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Changing the filter element on the condensate separator
The filter element is replaced at the same intervals as the carbon filter
canister.
To replace the filter element on the condensate separator, proceed as
follows:
1.
Open the profile clamp (12) and pull the base down and off.
The base contains approx. 1.5 liters of vacuum pump oil
(VE101).
2.
Remove the used filter element (2).
3.
Insert the new filter element (2).
4.
Check both O-rings (3) for damage. Replace it if necessary.
5.
Check the level on the inspection glass as described on page 76 of
Section Filling the condensate separator.
6.
Insert the base upwards into the upper part of the condensate
separator and close the profile clamp.
Checking the fill level on the condensate separator
Check the fill level of the vacuum pump oil (VE101) on the inspection glass of
the condensate separator.
During downtime (i.e. when the FAM is not in operation), the fill level must be
in the middle of the inspection glass.
If necessary, fill the condensate separator as described on page 76 in
Section Filling the condensate separator.
Filling the condensate separator
To fill up the condensate separator, proceed as follows:
1.
Open the profile clamp and remove the base in a downwards direction.
The base contains approx. 1.5 liters of vacuum pump oil
(VE101).
2.
Pour new vacuum pump oil (VE101) into the base via the tube.
3.
Check the fill level. At the very least, this should be in the middle of the
inspection glass.
4.
Insert the base into the top from below and close the profile clamp (12).