Error messages / Troubleshooting
FluidAqua Mobil - FAM10/15-P
en(us)
Page 89 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
2. Flow at FAM inlet has been too low for 5 minutes. Check the FAM inlet.
Cause:
This error can only arise in the starting phase of the
FAM, because it is only during this phase that the
corresponding timer is running. The message appears if
the MAX switch point in the vacuum column is not
achieved after 5 minutes have elapsed.
If this error occurs during initial start-up or after repairs,
it is advisable to fill the filling pump in advance with
approx. ¼ liters
of oil. To accomplish this, remove the
plug on the AS and then remove the AS by unscrewing
it. The oil is filled in through this opening. The AS and
the plug are mounted once again afterwards in order to
restart the FAM.
Remedy: Perform
the
following
steps:
Step
Description
1.
Message:
2. Flow at FAM inlet has been too low for 5 minutes. Check the
FAM inlet.
2.
Check all of the locking features in the suction line for flow.
3.
Actuate ESC key and reset failure with the F3 key.
4.
Start the unit by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 6.
5.
->b. The fault is not repeated.
-> proceed to Step 11.
6.
Clean the suction filter.
Check the hose between suction filter and filling pump.
Check the filling pump for proper functioning.
7.
Actuate ESC key and reset failure with the F3 key.
8.
Start the unit by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 10.
9.
->b. The fault is not repeated.
-> proceed to Step 11.
10.
Contact the HYDAC service department.
11.
The fault is repaired.