FAM Set-up and Connection
FluidAqua Mobil - FAM10/15-P
en(us)
Page 32 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
FAM Set-up and Connection
CAUTION
Rotary vane vacuum pump
Hazardous to health
►
Always make sure there is sufficient
ventilation in the surrounding area of the unit.
Air coming out of the rotary vane vacuum pump can contain particles of
vacuum pump oil and/or the fluid.
Depending on the composition of the oil and the composition of the gas,
there is a danger of damage to health if the emergent gas is inhaled over an
extended period of time.
Setting up the FAM
Observe the following points when setting up the unit:
Set up the unit horizontally on a level surface.
Special mounting is not required.
Lock the immobilization brakes on the wheels to avoid unintended
movement of the unit.
Set up the unit directly beside the tank that is to be cleaned.
Observe the maximum permitted suction pressure.
Make sure to note the ambient temperature on type label of the unit.
Ensure that the main switch is freely accessible at all times.
Keep an area of at least 0.8 m around the unit free for maintenance
purposes.
Make sure that the control panel is always freely accessible and that
the control cabinet can be opened fully.