FAM Set-up and Connection
FluidAqua Mobil - FAM10/15-P
en(us)
Page 36 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Connecting the inlet (IN)
The suction pressure at the FAM inlet must be -0.4 bar.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Note that the cross-section of the connected hoses/piping must be at least as
large as the cross-section of the inlet/outlet port sizes.
The shape of the tank connection should be set up in such a way that it will
always be lower than the level of the oil.
NOTICE
Contamination too high
The unit will be damaged
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
►
Never prime without a built-in suction strainer.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom of
the tank.
Connect outlet (OUT)
Take care to ensure that the maximum pressure of 2 bar is not exceeded at
the outlet.
NOTICE
OUT connection closed off
The unit will be damaged.
►
Check to be sure that all of the locking fixtures at the outlet are in
"open" position each time before start-up.
To prevent air from entering the medium, make sure that the
pressure hose with lance is always below the oil level in
operation.