Starting up the FAM
FluidAqua Mobil - FAM10/15-P
en(us)
Page 44 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Setting the pressure in the vacuum column
For the current pressure in the vacuum column, consult the control panel.
F1
F2
F3
F4
Pressure in the vacuum
column
Use the needle valve (D) to set the
pressure in the vacuum column.
Note that the pressure to be set in
the vacuum column is dependent
on the operating viscosity and the
water content.
Medium
Operating viscosity Pressure setting (absolute
pressure)
Hydraulic oil
50 mm
2
/s
≈
350 mbar
Ester oil
50 mm
2
/s
≈
400 mbar
Lubricating oil
300 mm
2
/s
≈
500 mbar
START
MENU1
RH+
P
Rel. moisture: Nominal:
30
%
Actual:33%
T
22°C P
970
Ready for operation. Please press Start
STOP
RESET