Shutting off the FAM
FluidAqua Mobil - FAM10/15-P
en(us)
Page 46 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Shutting off the FAM
F1
F2
F3
F4
F2 = STOP
F4 = back to "MENU1"
Press the "STOP" key. The power unit starts the after-run phase.
All of the pumps will be switched off, except for the evacuation pump.
Exception: If the heater is switched on, then a cooling phase of 60
seconds will intervene during which the heater is first shut off.
Afterwards, all of the pumps will be switched off, except for the
evacuation pump.
The evacuation pump runs until the "Min" fill level in the vacuum
column is reached. The run-down phase status is shown in the
display. The run-down phase status is shown in the display.
The FAM is once again ready for operation when the Start screen
appears on the display.
F1
F2
F3
F4
Close all locking features in the inlet and outlet lines.
Switch off the unit at the main switch.
MENU1
RH+
P
Rel. moisture: Nominal:
30
%
Actual:33%
T
22°C P
970
Automatic mode
STOP
Operating mode: Dewa Filtration
START
MENU1
Ready for operation, please press Start