Control panel basic (SIMATIC PANEL)
FluidAqua Mobil - FAM10/15-P
en(us)
Page 68 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Set (repeat testing interval) times
F1
F2
F3
F4
Display:
TRG MIN:
= Inspection repeating interval:
Is the time after which the FAM switches on
again after an automatic switch-off in the
operating mode "Dewater to" and "Filter to"
in order to check once again the relative
humidity and/or the purity of the fluid.
Adjustable from 2 – 360 minutes
Factory setting: 60 minutes
The settings apply only for the operating
modes FTT and DWT.
Elapsed minutes
= Display of the repeat testing interval minutes
that have already elapsed
MENU2
= Switch to MENU2
Read operating-hours counter
F1
F2
F3
F4
Display:
Operating hours
= Display of the FAM operating hours
MENU2
= Switch to MENU2
---------------------------------------------------------------------------------------------------
MENU2
Intervals
Repeat testing interval:
3
nominal minutes
0 elapsed minutes
MENU2
Operating hours
18 hours 43 minutes