Performing Maintenance
FluidAqua Mobil - FAM10/15-P
en(us)
Page 77 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Cleaning the suction strainer
NOTICE
Operation without a suction strainer
The pump will be destroyed
►
The unit may not be operated without the suction strainer.
►
Clean the suction screen regularly.
To protect the pump from coarse contamination particles and other foreign
bodies, a dirt trap with a strainer insert is fitted at the pump inlet.
Clean the suction strainer at regular intervals.
To install / dismount the suction screen, proceed as follows:
1. Unscrew the screw plug (1)
counterclockwise with an open-
jaw wrench.
2. Remove strainer insert (3) and
clean it.
3. To clean the suction screen,
wash it out with solvent and then
dry it using compressed air.
3. Check strainer insert (3) and the
seal ring (2) on the screw plug
for damage and replace if
necessary.
4. Install the new strainer insert (3).
5. Turn the screw plug (1)
clockwise manually.
Firmly screw in the screw plug
(1) with the open-jaw wrench.
6. After commissioning, check the
suction strainer fittings for leaks.
1
2
3