FCM Series
Changing the Filter Element
Change the filter element
1. Switch the unit off.
Pull power plug.
2. Depressurize the filter housing.
Remove the air bleed plug (1) in the
filter cover for this purpose.
The residual oil is drained through the
drain ball valve (2) into a suitable
container.
3. Loosen the four screws on the cover
counterclockwise.
4. Fold the screws down and press them
against the filter housing.
This pushes the cover of the filter
housing up.