FCM Series
Preparing the FCM for operation
Hanging / connecting the suction hose
NOTICE
Contamination too high
The unit will be damaged
►
Do not prime directly at the bottom of the tank
►
Do not prime in the sump
►
Never prime without a built-in suction screen
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Pull the suction hose (transparent hose) with lance out of the seat in the floor plate.
Put the suction hose with lance, without tension and or twist, into the appropriate
container and secure it.
Hanging / connecting the pressure hose
Pull out the pressure hose (black hose) with lance from the seat in the floor plate
and insert it in the appropriate receptacle.
Put the pressure hose with lance, without tension and or twist, into the appropriate
container and secure it.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 21 / 40
Bewa FCM 3160267d en-us 2012-01-24.doc
2012-01-24