Description of CANopen-Interface
HYDAC ELECTRONIC GMBH
07.10.2010
Mat. No. 669824
Page 51 of 63
9.3 Object 6010h: Preset value
WARNING !
Risk of injury and damage to property by an actual value jump when the Preset
adjustment function is performed!
•
The preset adjustment function should only be performed when the measuring
system is at rest, otherwise the resulting actual value jump must be permitted in
the program and application!
The Preset Function can be used to adjust the measuring system to any position
value within a range of 0 to measuring length in increments –1.
The output position value is set to the parameter "Preset value" when writing to this
object.
Signed32
Preset value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
Index
Sub index
Comment
Type
6010h
0
Highest sub-index supported
Unsigned8
1
Preset value
Signed32
Sub index0
: The entry at sub-index 0 contains the highest sub-index that is supported.
Value = 1.
Sub index1:
The entry at sub-index 1 contains the preset value for the position output.